You can download a .pdf of this Tech Note from AMX at: http://www.amx.com/techsupport/PDFs/981.pdf
Camera Controllers
PTE-300
- Default IP Address: 192.168.1.160
- Default Baud Rate: 9600,N,8,1
Central Controllers
NI Series
- Default Administrator User Name: administrator
- Default Administrator Password: password
- Default User Name: NetLinx
- Default Password: password
Reset to Factory Defaults:
- See NetLinx Studio or the Master Configuration Manager webpages
Digital Signage
IS-PLAYER-200
- Default IP Address: DHCP (zero-config)
IS-SPX-1000
- Default IP Address: DHCP (zero-config)
- Default User Name: <none>
- Default Password: <none>
Reset to Factory Defaults:
- Unplug the unit from the power.
- Push the reset button and keep it pressed.
- Power up the IS-SPX-1000 unit.
- Wait with the reset button pressed for at least 8 seconds.
- Release the reset button.
IS-XPT-2000
- Default IP Address: DHCP (zero-config)
Endeleo
UDM-0102
- Default IP Address: 192.168.0.96
- Default User Name: <leave blank>
- Default Password: admin
- Default Baud Rate: 9600,N,8,1 No Flow Control
UDM-0404
- Default IP Address: 192.168.0.96
- Default User Name: <leave blank>
- Default Password: admin
- Default Baud Rate: 9600,N,8,1, No Flow Control
UDM-0808-SIG
- Default IP Address: DHCP (zero-config)
- Default User Name: administrator
- Default Password: password
Reset to Factory Defaults:
- Use the ‘RESETFACTORY’ command or Use the WebConsole’s Security Settings tab
UDM-1604(B)
- Default IP Address: 192.168.0.96
- Default User Name: <leave blank>
- Default Password: admin
- Default Baud Rate: 9600,N,8,1, No Flow Control
Reset to Factory Defaults:
- Use the ‘Hub Reset’ option in the Configuration Webpages, then cycle power
UDM-1604C
- Default IP Address: 192.168.0.96
- Default User Name: <leave blank>
- Default Password: admin
- Default Serial Port: 9600, N, 8, 1, No Flow Control
Reset to Factory Defaults:
- Use the ‘Reset Hub’ option in the Configuration Webpages, then cycle power
Environmental Controls
ENV-VST-C
- Default Password: 1988
- Restore to Factory Defaults:
- Use the ‘ZAP!’ command
ViewStat
- Default Password: 7777
Network/Communication
CSG (Communications Gateway)
- Default IP Address: 192.168.69.1
- Default User Name: admin
- Default Password: 1988
Reset to Factory Defaults:
- Use the ‘Factory Reset’ tab in the web pages or press the Reset Switch on the rear panel continuously during the boot process.
MET-ECOM/-D
- Default IP Address: DHCP (zero-config)
- Default User Name: Admin
- Default Password: 1988
Reset to Factory Defaults:
- Push and hold the ID/Reset pushbutton on the rear panel for at least 10 seconds.
NXA-ENET8POE
- Default IP Address: 192.168.2.10
- Default User Name: admin
- Default Password: 1988
Reset to Factory Defaults:
- Remove the power cord from the back of the device.
- Remove all cables from the front-panel ports.
- Connect port 1 to port 2 on the front panel, using a standard network cable.
- Reconnect the power cord to the rear of the switch.
- The PoE LEDs (FIG. 1) will flash on and off at least two times, followed by the ƒn Link/ACT LEDs. Do not disconnect the cable or the power cord until only the first two Link/ACT LEDs are a steady green and the others are off.
- Disconnect the power cord and THEN disconnect the network cable.
- Reconnect the power cord. The NXA-ENET8POE is now reset to its factory defaults.
NXA-ENET24
- Default IP Address: DHCP
- Default Privileged User Name: Admin
- Default Privileged Password: 1988
- Default Normal Exec User Name: guest
- Default Normal Exec Password: guest
Reset to Factory Defaults:
- The switch’s system defaults are provided in the configuration file “Factory_Default_Config.cfg.” To reset the switch defaults, this file should be set as the startup configuration file.
NXA-WAP200G
- Default IP Address: 192.168.1.240
- Default User Name: Admin
- Default Password: 1988
Reset to Factory Defaults:
- Press the Reset button on the rear panel for 10 seconds
NXA-WAP250G
- Default IP Address: 192.168.1.240
- Default User Name: Admin
- Default Password: 1988
Reset to Factory Defaults:
- Hold down the reset button on the bottom panel for 10 seconds or more, any configuration changes you may have made are removed, and the factory default configuration is restored to the access point.
NXA-WAP1000
- Default IP Address: 192.168.0.1
- Default User Name: admin
- Default Password: 1988
Reset to Factory Defaults:
- Pressing and holding the Hard Reset button on the rear panel for six seconds resets the unit to factory default settings.
NXA-WAPZD1000 (Zone Director)
- Default IP Address: DHCP/ 192.168.0.2
- Note: The NXA-WAPZD1000 is shipped with its default IP address settings as “DHCP”, but if it is installed outside of a DHCP network, the device will revert to the default IP address (192.168.0.2).
- Default User Name: admin
- Default Password: admin
Reset to Factory Defaults:
- Press and hold the Reset button for 8 seconds. The Status LED will now start flashing green to denote its default status.
NXR-ZGW/-ZRP
- Default IP Address: 192.168.1.140
- Default User Name: Admin
- Default Password: 1988
Reset to Factory Defaults:
- Press and hold the ID Button for approximately 30 seconds to return the NXR-ZGW to factory default settings.
NXR-ZGW-PRO/-ZRP-PRO
- Default IP Address: DHCP/169.254.1.2
- Note: The NXR-ZGW-PRO is shipped with its default IP address settings as “DHCP”, but if it is installed outside of a DHCP network, the device will revert to the default IP address (169.254.1.2).
- Default User Name: Admin
- Default Password: 1988
Reset to Factory Defaults:
- Press and hold the ID Button for approximately 30 seconds to return unit to factory default settings.
Television Distribution System
DTV-TX Transmitter
- Default IP Address: DHCP
Reset to Factory Defaults:
- In the Configuration Manager, Click to reset the Network Settings for selected Transmitter to DHCP.
DTV-RX Receiver
- Default IP Address: DHCP
TVM-1600
- Default IP Address: 192.168.0.96
- Default User Name: <leave blank>
- Default Password: admin
Video Management/Distribution
MAX Server
- Default IP Address: 192.168.1.30
- Default User Name: root
- Default Password: mozart
MAX-CSD10
- Default IP Address: DHCP
- Default User Name: administrator (Web Interface)
- Default Password: password (Web Interface)
Reset to Factory Defaults:
- Press and hold the ID button on the front panel for 10 seconds to reset the parameters and reboot the MAX unit.
MAX-CSE
- Default IP Address: DHCP
- Default User Name: administrator (Web Interface)
- Default Password: password (Web Interface)
Reset to Factory Defaults:
- Press and hold the ID button on the front panel for 10 seconds to reset the parameters and reboot the MAX unit.
V2 Server
- Default IP Address: DHCP
- Note: (use ‘ping V2AMX-<SVCTAG>’ to find IP address. <SVCTAG> is the service name, which you can find on the front of your server.
- Default User Name: Administrator
- Default Password: vision2
Related posts:
- Oh yeah, ICSNet requires termination
- AMX IR Files for Firebird tuner
- Map of Videoconferencing Sites in Missouri
- Civility and Civil Public Discourse: The Next Generation
- Civility and Civil Discourse
- Some new VTC Test Sites
- Checklist: Basic VCS Expressway Security
- How to go from 4 to 3 footer widgets in the WP TwentyTen Theme
- My Iphone is watching me!
- Radvision Interop: from desktop to telepresence.
- H323 Test Sites in Polycom Address book Format
- Installing short-throw Projectors in rooms with low ceilings.
- H323 Test Sites UPDATED
- List of Videoconferencing Sites in Missouri
- 5 Techniques for Preventing Deadline Stress as a Project Manager